Mansfield manufactures comprehensive range of air-frame wiring and ancillary cables to meet conditions of air-frame wiring and ancillary cables to meet conditions of aircraft and ships. Cables conforming to B. I. S., British Standards or defence specifications can be supplied in accordance with customer requirements.
also supplies minature cables and flexible equipment wires for testing/Laboratory purposes apart from composite and Grab cables.
The cables are resistant to Toxic Vapour, oils and heart and are robust with other distinctive properties. Many aircrafts wiring cables are also suitable for industrial applications.
Mansfield Pren aircraft wiring cables which are suitable for use at established conductor temperature upto 90oC, conform in all respects to BS: 2E: 21 (Pren type electrical cable for aircraft).
In the manufacture of cables, standard lay down operating procedures at each and every stage are followed to achieve quality. For quality end products, control starts from proper design of the product. All raw materials are selected carefully and only materials of high quality are used in production. Having done this, stage wise inspection is done to ensure conformity with relevant Indian/International Standards.
CStage-Wise Inspection | |
Wire Drawing | Circular Stranded/Solid Aluminium/Copper conductor as per IS: 8130 |
From 16 Sq mm onwards | Shaped/Circular Standard/Solid Aluminium/Copper |
Insulation | PVC/FR grade PVC/XLPE |
Inner Sheath | PVC/FR grade PVC/FRLS PVC |
Unarmoured/Armoured | G.S. Wire/Flat Strp/Aluminium Wire |
Outer Sheath | PVC/FR PVC/FRLS PVC |
Sizes Single Core | 10 sq mm-630 sq mm |
Multi Core | 6 sq mm-300 sq mm |
Standard | IS 1554 Part1, IS 7098 Part 1 |
The tests on cables have been classified broadly in four categories as follows:
Tests carried out on each Cable to check the requirement which are likely to vary during production.
Tests carried out to prove conformity with the specification. These are intended to prove the general qualities and design of a given type of cable.
ests carried out on samples taken from a lot for the purpose of acceptance of the lot.
Special tests are carried out when required by agreement between the purchaser and the manufacturer. Special tests required for FRLS Cables can also be carried out at our works i.e. Halogen gas generation test to IEC-754 (part-1) , Smoke generation test to ASTMD-2843, Oxygen Index test and Temperature Index test to AS T MD -2863, Flammability test to (1) IEC -332-3., flame resistant test to IEEE-383.